Build Result errors come from the A3200 compiler and are not directly decoded to text. If you do not find the exact Build Result error listed below, create a technical support case for further review.

Build Result: -536325584 = "Same axis name assigned to two axes"

  • Double check the axis names in the parameter file.

Build Result: -536325727 = Corrupted .OGM file

  • Delete the .OGM file and recompile and reload the program. 
  •  Reinstall the A3200 software

Build Result: -536326114 = "File out of date with object"
or Build Result: -536326118 = "Object file version bad; recompile from source"

...

  • One possibility is that one or more file paths (path to the PGM file, path to an include file or PGM file set in Program Automation) is invalid or more than 255 characters.

Build Result: -536325584 = "Same axis name assigned to two axes"

  • Double check the axis names in the parameter file.