Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Expand
titleA timeout occurred while waiting for an asynchronous receive event
  • Reinstall A3200 and its real-time operating system, INtime:

    1. Uninstall A3200
    2. Uninstall INtime (separate program from A3200)
    3. Restart the PC
    4. Reinstall A3200 (INtime is installed automatically)
    5. Restart the PC
  • Pass the FireWire/HyperWIre card to INtime control.
    1. Open INtime Configuration
    2. Double click on INtime Device Manager.
    3. Right click on the FireWire card and select Pass to INtime using Polling

      Expand
      titleFigure 1-1


    4. For HyperWire cards, Pass to INtime using MSI

      Expand
      titleFigure 1-2


    5. Navigate to File > Save Configuration. Exit INtime Device Manager and restart the PC.
  • The FireWire/HyperWire card could be defective. Replace the FireWire/HyperWire card.
  • Verify that your FireWire or HyperWire cables are working correctly. Test each cable separately. If necessary, replace the FireWire or HyperWire cable.
  • Optimize the PC. This can be done by following the Optimizing A3200 Performance guide on our website. This includes a list of Windows and BIOS settings that are known to negatively affect real time performance which can cause communication issues.
  • The drive/controller hardware in the system could be defective. Replace the drive/controller.


Content by Label
showLabelsfalse
max5
spacesAKB
showSpacefalse
sortmodified
reversetrue
typepage
cqllabel in ("a3200","isochronous","error","communication") and type = "page" and space = "AKB"
labelsisochronous communication error a3200

...