When upgrading to Windows 10, A3200 must be upgraded to at least version 5.03. Not all Npaqs are capable of being upgraded, only those manufactured after 2007 may be upgradeable, as determined below.

Step-by-step guide

  1. Download and run our compatibility testing program, this will determine whether your Npaq can be run with versions of A3200 above 4.xx.
    1. For A3200 versions 2.xx, download NpaqCompatibilityCheck.pgm
    2. For A3200 versions 4.xx, download NpaqCompatibilityCheck4.pgm


If the Npaq CompatibilityCheck program fails, you'll have to locate the control board revision inside the Npaq:

  1. Remove the cover of the Npaq.
  2. Locate the control board. The control board is on the left side while facing the front of the unit, and has the FireWire connectors as well as red and white Communication Channel switches.
  3. Locate the revision, which is typically located in the bottom left or bottom right of the board. Revisions can be -, A, or B. If you have an MXR board installed, this may be difficult to see.
  4. Only revision B is upgradeable, revisions - and A are obsolete.



  • No labels